HideChilds = False
SystemName =

Water Level Control Valves

FL - MODULATING FLOAT CONTROL VALVE

Modulating Float Control Valve

  • Model 30-FL
  • Model 68-FL

 

The main valve is controlled by a float assembly, located in the tank or reservoir and set to the required maximum water level. The valve constantly maintains the maximum level. 

Features:

  • Accurate level control
  • Simple and reliable design
  • Easy installation and maintenance
  • The application is based on the UL listed valves

FLEL - ELECTRIC FLOAT CONTROL VALVE

Electric Float Control Valve

  • Model 30-FLEL
  • Model 68-FLEL

 

The main valve is actuated by a 3-way solenoid to an electric sensor float, located in the tank/reservoir. The sensor provides open and close commands to the solenoid valve. The main valve fully opens and closes drip tight upon command, when the solenoid is de-energized, thus enabling accurate and reliable differential level control. Optional Addition: dinamic surge-preventing closing.

Features:

  • Accurate differential level control
  • Low power electric actuation
  • Fast response
  • Simple and reliable design
  • Easy installation and maintenance
  • The application is based on the UL listed valves

FLDI - DIFFERENTIAL FLOAT PILOT CONTROL VALVE

Differential Float Pilot Control Valve

  • Model 68-FLDI
  • Model 30-FLDI

 

The main valve is controlled by a float assembly, closing it when the water reaches maximum level, and opening it when the water drops to its preset minimum level. The differential between the maximum and the minimum levels is adjustable. Optional addition: dynamic, surge preventing shutoff. 

Features:

  • Accurate differential level control
  • Adjustable differential
  • Fast response
  • Simple and reliable design
  • Easy installation and maintenance
  • The application is based on the UL listed valves

 

AL - ALTITUDE PILOT CONTROL VALVE

Altitude Pilot Control Valve

  • Model 68-AL
  • Model 30-AL

 

The valve is actuated by a highly sensitive altitude pilot, located outside the tank. The pilot opens or closes the valve in response to the static pressure of the water. The pilot allows for differential adjustments between the maximum and minimum level. Optional addition: dynamic, surge preventing shutoff. 

Features:

  • Accurate differential level control
  • Fast response
  • Easy access - no float is located in the tank\reservoir
  • Simple and reliable design
  • Easy installation and maintenance
  • The application is based on the UL listed valves
TemplateTags() in code (Designs/Dorot/_parsed/ContentWide.parsed.cshtml). Remove before going live...